SIMBAD references

2013MNRAS.433.3062B - Mon. Not. R. Astron. Soc., 433, 3062-3078 (2013/August-3)

Flux calibration of the Herschel-SPIRE photometer.

BENDO G.J., GRIFFIN M.J., BOCK J.J., CONVERSI L., DOWELL C.D., LIM T., LU N., NORTH C.E., PAPAGEORGIOU A., PEARSON C.P., POHLEN M., POLEHAMPTON E.T., SCHULZ B., SHUPE D.L., SIBTHORPE B., SPENCER L.D., SWINYARD B.M., VALTCHANOV I. and XU C.K.

Abstract (from CDS):

We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging Receiver instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers and tests of the flux calibration on observations of primary and secondary calibrators. The procedure for deriving the flux calibration parameters is divided into two parts. In the first part, we use observations of astronomical sources in conjunction with the operation of the photometer internal calibration source to derive the unscaled derivatives of the flux calibration curves. To scale the calibration curves in Jy beam-1 V-1, we then use observations of Neptune in which the beam of each bolometer is mapped using a very fine scan pattern. The total instrumental uncertainties in the flux calibration for most individual bolometers is ∼ 0.5percent, although a few bolometers have uncertainties of ∼ 1-5percent because of issues with the Neptune observations. Based on application of the flux calibration parameters to Neptune observations performed using typical scan map observing modes, we determined that measurements from each array as a whole have instrumental uncertainties of 1.5percent. This is considerably less than the absolute calibration uncertainty associated with the model of Neptune, which is estimated at 4percent.

Abstract Copyright: © 2013 The Authors Published by Oxford University Press on behalf of the Royal Astronomical Society (2013)

Journal keyword(s): instrumentation: photometers

Simbad objects: 5

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2013MNRAS.433.3062B and select 'bookmark this link' or equivalent in the popup menu