SIMBAD references

2020MNRAS.492..480R - Mon. Not. R. Astron. Soc., 492, 480-487 (2020/February-2)

Uncooled microbolometer arrays for ground-based astronomy.

RASHMAN M.F., STEELE I.A., BATES S.D., COPLEY D. and LONGMORE S.N.

Abstract (from CDS):

We describe the design and commissioning of a simple prototype, low-cost 10 µm imaging instrument. The system is built using commercially available components including an uncooled microbolometer array as a detector. The incorporation of adjustable germanium reimaging optics rescale the image to the appropriate plate scale for the 2 m diameter Liverpool Telescope. From observations of bright Solar system and stellar sources, we demonstrate a plate scale of 0.75 arcsec per pixel and confirm the optical design allows diffraction limited imaging. We record a ∼10 {per cent} photometric stability due to sky variability. We measure a 3σ sensitivity of 7 x 103 Jy for a single, ∼0.11 s exposure. This corresponds to a sensitivity limit of 3 x 102 Jy for a 60 s total integration. We present an example science case from observations of the 2019 January total lunar eclipse and show that the system can detect and measure the anomalous cooling rate associated with the features Bellot and Langrenus during eclipse.

Abstract Copyright: © 2019 The Author(s) Published by Oxford University Press on behalf of the Royal Astronomical Society

Journal keyword(s): instrumentation: detectors - Moon - infrared: general - infrared: planetary systems

Simbad objects: 1

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2020MNRAS.492..480R and select 'bookmark this link' or equivalent in the popup menu