SIMBAD references

2016A&A...592A..70H - Astronomy and Astrophysics, volume 592A, 70-70 (2016/8-1)

Gaia FGK benchmark stars: new candidates at low metallicities.

HAWKINS K., JOFRE P., HEITER U., SOUBIRAN C., BLANCO-CUARESMA S., CASAGRANDE L., GILMORE G., LIND K., MAGRINI L., MASSERON T., PANCINO E., RANDICH S. and WORLEY C.C.

Abstract (from CDS):

Context. We have entered an era of large spectroscopic surveys in which we can measure, through automated pipelines, the atmospheric parameters and chemical abundances for large numbers of stars. Calibrating these survey pipelines using a set of "benchmark stars" in order to evaluate the accuracy and precision of the provided parameters and abundances is of utmost importance. The recent proposed set of Gaia FGK benchmark stars has up to five metal-poor stars but no recommended stars within -2.0<[Fe/H]< -1.0dex. However, this metallicity regime is critical to calibrate properly. Aims.In this paper, we aim to add candidate Gaia benchmark stars inside of this metal-poor gap. We began with a sample of 21 metal-poor stars which was reduced to 10 stars by requiring accurate photometry and parallaxes, and high-resolution archival spectra.
Methods. The procedure used to determine the stellar parameters was similar to the previous works in this series for consistency. The difference was to homogeneously determine the angular diameter and effective temperature (Teff) of all of our stars using theInfrared Flux Method utilizing multi-band photometry. The surface gravity (logg) was determined through fitting stellar evolutionary tracks. The [Fe/H] was determined using four different spectroscopic methods fixing the Teff and logg from the values determined independent of spectroscopy.
Results. We discuss, star-by-star, the quality of each parameter including how it compares to literature, how it compares to a spectroscopic run where all parameters are free, and whether FeI ionisation-excitation balance is achieved.
Conclusions. From the 10 stars, we recommend a sample of five new metal-poor benchmark candidate stars which have consistent Teff, logg, and [Fe/H] determined through several means. These stars, which are within -1.3<[Fe/H]< -1.0, can be used for calibration and validation purpose of stellar parameter and abundance pipelines and should be of highest priority for future interferometric studies.

Abstract Copyright: © ESO, 2016

Journal keyword(s): stars: fundamental parameters - techniques: spectroscopic - standards

VizieR on-line data: <Available at CDS (J/A+A/592/A70): sources.dat tablea1.dat-tablea10.dat>

Simbad objects: 31

goto Full paper

goto View the references in ADS

To bookmark this query, right click on this link: simbad:2016A&A...592A..70H and select 'bookmark this link' or equivalent in the popup menu